Residential Building Inspection Report
Inspection
Date:
Prepared
For:
Prepared
By:
House To Home Inspections LLC
513-255-0298
house2home@tds.net
Dayton office
Report
Number:
Inspector:
© 2006 House To Home Inspections-cincinnati - dayton ohio
:::::::::::::::::::::::This IS A REDUCED SIZED SAMPLE REPORT:::::::::::::::::::::::::
Report Overview 3
Structure 5
Roofing 11
Exterior 16
Electrical 19
Heating 24
Cooling / Heat Pumps 27
Insulation /
Ventilation 29
Plumbing 30
Interior 33
Appliances 37
For your convenience, the following conventions have been used in this report.
Major Concern: a system or component which is considered significantly deficient or is unsafe. Significant deficiencies need to be corrected and, except for some safety items, are likely to involve significant expense.
Safety Issue: denotes a condition that is unsafe and in need of prompt attention.
Repair: denotes a system or component which is missing or which needs corrective action to assure proper and reliable function.
Improve: denotes improvements which are recommended but not required.
Monitor: denotes a system or component needing further investigation and/or monitoring in order to determine if repairs are necessary.
Please note that those observations listed under “Discretionary Improvements” are not essential repairs, but represent logical long term improvements.
The following is a synopsis of the potentially significant improvements that should be budgeted for over the short term. Other significant improvements, outside the scope of this inspection, may also be necessary. Please refer to the body of this report for further details on these and other recommendations.
All components designated for inspection in the NACHIâ Standards of Practice are inspected, except as may be noted in the “Limitations of Inspection” sections within this report.
It is the goal of the inspection to put a homebuyer in a better position to make a buying decision. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind.
A Home inspection is a
non-invasive visual examination of a residential dwelling, performed for a fee,
which is designed to identify observed material defects within specific
components of said dwelling. Components may include any combination of
mechanical, structural, electrical, plumbing, or other essential systems or
portions of the home, as identified and agreed to by the Client and Inspector,
prior to or during the inspection process.
I. A home inspection is
intended to assist in evaluation of the overall condition of the dwelling. The
inspection is based on observation of the visible and apparent condition of the
structure and its components on the date of the inspection and not the
determination of future conditions.
II. A home inspection will
not reveal every problem that exists or ever could exist, but only those
material defects observed on the day of the inspection.
1.2. A Material defect is a
problem with a residential real property or any portion of it that would have a
significant adverse impact on the value of the property or that involves an
unreasonable risk to people on the property. The fact that a structural
element, system or subsystem is near, at or beyond the end of the normal useful
life of such a structural element, system or subsystem is not by itself a
material defect.
1.3. An Inspection report shall describe and identify in written format the inspected systems, structures, and components of the dwelling and shall identify material defects observed. Inspection reports may contain recommendations regarding conditions reported or recommendations for correction, monitoring or further evaluation by professionals.
Please refer to the pre-inspection contract for a full explanation of the scope of the inspection.
Foundation: ·Concrete
Block ·Basement
Configuration
Columns: ·Steel
Floor Structure: ·Wood
Joist
Ceiling Structure: ·Joist
Roof Structure: ·Rafters ·Spaced Plank Sheathing
Foundation
· Monitor: Common minor settlement cracks were observed in the foundation walls. This implies that some structural movement of the building has occurred. These cracks did not extend all the way through to the interior. Cracks of this type should be watched for any sign of additional movement. In the absence of any sign of ongoing movement, repair should not be necessary.
Back of House
Side of House
Major Concern:
Repair: Larger than typical
foundation settlement cracking was observed. The amount of movement which has
occurred is not likely to have caused other damage to the structure but this
area should be repaired and continuously monitored. If additional movement
occurs, more costly repairs might be necessary. The rate of movement cannot be
predicted during a one-time inspection. House To Home Inspections recommends
that a certified professional be called to further evaluate and repair.
Front of House. Paneling in basement restricted complete view.
Crack under side basement window extends all the way into interior.
Interior view of major crack above.
· Improve: Surface deterioration (spalling, crumbling material) was observed on the back porch pad. This condition is common in many old homes and does not usually represent a serious structural concern unless there is substantial loss of material. In an effort to prevent long-term deterioration, it would be wise to consider parging (a concrete stucco-like coating) over deteriorated areas. Lot drainage improvements and elimination of water or roof runoff splashing against foundation walls as outlined in the Exterior section of this report are also recommended.

Floors
· Monitor: The floor structure shows common sagging and movement. This is usually the result of the age and framing design of the building. There was not evidence of need for immediate, costly repair.
· Improve: Main Steel support columns are not bolted or welded to main support beams throughout.
Wood Boring Insects
· Monitor: Although there was no visible evidence of prior or current termite damage or infestation, this home is in an area known for termite activity. Termites can do a substantial amount of damage to the wood structural components of a home. Any form of wood/soil contact should be avoided. Controlling dampness in the soil around the perimeter of a home, including below porches and in crawl spaces, is recommended. Preventative chemical treatment, performed by a licensed pest control specialist, is also advisable.
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:
· Structural components concealed behind finished surfaces could not be inspected.
· Only a representative sampling of visible structural components were inspected.
· Furniture and/or storage restricted access to some structural components.
· Engineering or architectural services such as calculation of structural capacities, adequacy, or integrity are not part of a home inspection.
The inspector is not required to:
Enter any crawlspaces that are not readily accessible or where
entry could cause damage or pose a hazard to the inspector in his or her
opinion.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or adequacy of foundation bolting,
bracing, joists or support systems.
E. Provide any engineering or architectural service.
F. Report on the adequacy of any structural system or component.
Observed Limitations:
Access limited in side attic areas due to storage.

Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Roof Covering: ·Asphalt
Shingle
Roof Flashings: ·Metal
Chimneys: ·Masonry
Roof Drainage System: ·Aluminum ·Downspouts
discharge below grade
Method of Inspection: ·Walked on roof
General Comments
The roof coverings are old and are at or near end of useful life.
Sloped Roofing
· Monitor: The roofing is near the end of its life. Watch for leaks and expect to replace the roof soon.
· Repair: An area of shingles is severely deteriorated and curled in the back. Damaged or missing roofing material should be repaired immediately.
· It is recommended that the present layers of roofing materials be removed prior to re-roofing. This adds cost of demolition and debris removal to the re-roof cost.

· Replace the roof flashing materials when re-roofing to avoid leaks in these areas.

Chimneys
· Monitor: The chimney is no longer in service. It could be removed down to a level below the roof line.
· Repair: Masonry chimney is cracked in the attic space. Some mortar joints need repaired.

Gutters & Downspouts
· Monitor: The downspouts that discharge below grade level should be monitored. If they are ever suspected to be clogged or disconnected below grade, they should be redirected to discharge at least five (5) feet from the building. Foundation leakage adjacent to a downspout is an indication of a problem below grade. A downspout discharge appears to have been unearthed in the backyard but, appears that it’s discharge is far enough away from the house.
Discretionary Improvements
Covering the gutters with a protective mesh may help to avoid congestion with leaves and debris.
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:
· Not all of the underside of the roof sheathing is inspected for evidence of leaks.
· Evidence of prior leaks may be disguised by interior finishes.
· Antennae, chimney/flue interiors which are not readily accessible are not inspected and could require repair.
· Roof inspection may be limited by access, condition, weather, or other safety concerns.
The inspector is not required to:
A. Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage pipes.
D. Remove snow, ice, debris or other conditions that prohibit the observation
of the roof surfaces.
E. Inspect antennae, lightning arresters, or similar attachments.
Observed Limitations:
Storage in attic blocked access to side attic areas.
Chimney had material inside preventing inspection of interior
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Wall Covering: ·Brick
Eaves, Soffits, And Fascias: ·Wood ·Aluminum
Exterior Doors: ·Metal
Window/Door Frames and Trim: ·Wood
Entry Driveways: ·Asphalt
·Concrete
Porches, Decks, Steps, Railings: ·Concrete
Overhead Garage Door(s): ·Wood
Surface Drainage: ·Level Grade ·Graded
Away From House
Retaining Walls: ·Block
Positive Attributes
The auto reverse mechanism on the overhead garage door responded properly to testing. This safety feature should be tested regularly as a door that doesn’t reverse can injure someone or fall from the ceiling. Refer to the owner’s manual or contact the manufacturer for more information.
General Comments
The exterior of the home has not been well maintained. Repairs are needed.
Exterior Walls
· Repair: Localized pointing of deteriorated mortar between the bricks of the exterior walls is advisable in a few locations to prevent further deterioration.
· Repair: The siding should be painted in front to preserve the building.
Exterior Eaves
· Repair: The fascia throughout should be painted.
Windows
· Repair: The window frames in various locations require painting and caulking. Exterior windowsills are cracked in some locations.

Garage
· Monitor: The garage floor slab and walls have typical cracks usually the result of shrinkage and/or settling of the slab. Floor cracks more than 1/8” high could present a trip hazard.
· Improve: Shed is dilapidated in back.
· Repair: Front storm door closer missing.
Driveway
Monitor: Common minor cracks throughout.
Walkway
· Repair, Safety Issue: The walkway along the left hand side of the home presents a trip hazard. This condition should be altered for improved safety.
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:
· A representative sample of exterior components was inspected rather than every occurrence of components
that were tested.
The inspector is not required to:
A. Inspect or operate screens, storm windows, shutters, awnings,
fences, outbuildings, or exterior accent lighting.
B. Inspect items, including window and door flashings, which are not visible or
readily accessible from the ground.
C. Inspect geological, geotechnical, or hydrological conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window seals or damaged glass.
Observed Limitations:
· Landscape components restricted a view of some exterior areas of the house.
· Storage in the garage restricted the inspection.
· Access below decks and/or porches was not possible.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Size of Electrical Service: ·Unable To Determine
Service Drop: ·Overhead
Service Entrance Conductors: ·Aluminum
Service Equipment &
Main Disconnects: ·Main Service Rating ???
Amps ·Breakers
Service Grounding: ·Copper
Distribution Wiring: ·Copper
Wiring Method: ·Tinned-Copper
Switches & Receptacles: ·Grounded
and Ungrounded
Ground Fault Circuit Interrupters: ·Kitchen
General Comments
Major Concern: The electrical system is obsolete. Improvement should be high priority for safety reasons. Unsafe electrical conditions represent a shock hazard. A licensed electrician should be consulted.
Main Panel
· Major Concern, Repair: The main distribution panel is obsolete and should be replaced.

· Repair: The main distribution panel does not contain enough circuits to properly serve the home. A larger panel or an auxiliary would be desirable.
· Safety Issue: Repair: Main distribution panel is rated to accept 125 amps but, breaker labeled as “main” in the panel shows 60 amps. The main breaker is usually the deciding factor on how many amps a panel will accept. An electrician should rectify this situation.
· Repair: Circuits within the main distribution panel that are doubled up (referred to as “double taps”) should be separated. Each circuit should be served by a separate fuse or breaker. Also hot (black) wire appears to be overheated in breaker labeled as “window”.

Distribution Wiring
· Repair: All junction boxes should be fitted with cover plates, in order to protect the wire connections.
Outlets
· Repair: An outlet in the dining room is inoperative. This outlet and circuit should be investigated.
· Repair: Ungrounded 3-prong outlets throughout the home should be repaired. In some cases a ground wire may be present in the electrical box and simply needs to be connected. If no ground is present “repair” can be as simple as filling the ground slot with epoxy. Better, since having a ground increases safety, a grounded circuit could be strung to this outlet, or a separate ground wire could be connected. Some electrical codes allow the installation of a ground fault circuit interrupter (GFCI) type outlet where grounding is not provided. In this case the GFCI may work but can’t be tested by normal means.
· Improve: Outlets are loose in the garage.
Switches
· Repair: The loose light switch in various locations should be secured.
Lights
· Repair: Lights in various locations are inoperative. If the bulbs are not blown, the circuit should be repaired.
· Repair: The light pole in the front yard is not secure and is ready to fall over.
Discretionary Improvements
The installation of ground fault circuit interrupter (GFCI) devices is advisable on exterior, garage, bathroom and some kitchen outlets. Any whirlpool or swimming pool equipment should also be fitted with GFCI’s as they offer protection from shock or electrocution.
Grounded outlets may be desirable in some areas where ungrounded outlets exist. This will depend on electrical needs.
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:
· Electrical components concealed behind finished surfaces are not inspected.
· Only a representative sampling of outlets and light fixtures were tested.
· Furniture and/or storage restricted access to some electrical components which may not be inspected.
· The inspection does not include remote control devices, alarm systems and components, low voltage wiring, systems, and components, ancillary wiring, systems, and other components which are not part of the primary electrical power distribution system.
The inspector is not required to:
A. Insert any tool, probe or device into the main or sub-panels.
B. Operate electrical systems that are shut down.
C. Remove panel covers or dead front covers if not readily accessible.
D. Operate over current protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage of the main service if not
visibly labeled.
G. Inspect the alarm system and components.
H. Inspect the ancillary wiring.
I. Activate any electrical systems or branch circuits which are not energized.
J. Operate overload devices.
K. Inspect low voltage systems, electrical de-icing tapes, swimming pool wiring
or any time-controlled devices.
L. Verify the continuity of the connected service ground.
M. Inspect private or emergency electrical supply sources, including but not
limited to generators, windmills, photovoltaic solar collectors, or battery or
electrical storage facility.
N. Inspect spark or lightning arrestors.
O. Conduct drop voltage calculations.
P. Determine the accuracy of breaker labeling.
Observed Limitations:
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Energy Source: ·Gas
Heating System Type: ·Forced Air Furnace
Vents, Flues, Chimneys: ·Plastic
Heat Distribution Methods: ·Ductwork
General Comments
The heating system not been maintained.
Furnace
· Repair: The heating system requires service. This should be a regular maintenance item to assure safe, reliable heat.
· Repair: Water leak coming from condensation area of the drain hose.

· Repair: Kill switch on bottom service panel is broken.
· Improve: Rust on interior supply gas piping.

Supply Air Ductwork
· Monitor: Supply airflow in many locations is less than ideal. Rebalancing the ductwork, blower cleaning or repairs, filter replacement, or additional ductwork may be needed to obtain good airflow.
Thermostat
· Monitor: The thermostat is old and may be temperamental. Replacement is a minor job.
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:
The inspector is not required to:
A. Inspect or evaluate interiors of flues or chimneys, fire chambers, the heat exchanger, the humidifier or dehumidifier, the electronic air filter, solar heating systems or fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature, flow, balance, distribution, size,
capacity, BTU, or supply adequacy of the heating system.
D. Light pilot flames.
E. Activate heating, heat pump systems, or other heating systems when ambient
temperatures or other circumstances are not conducive to safe operation or may
damage the equipment.
F. Operate electronic thermostats.
G. Evaluate fuel quality.
Observed Limitations:
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Energy Source: ·240-Volt
Power Supply
Central System Type: ·Air Cooled Central Air Conditioning
General Comments
The system is showing some signs of age and may require a higher level of maintenance. This system has not been maintained. The system responded properly to operating controls during restricted testing (see limitations section).

Central Air Conditioning
· Monitor: The fins of the outdoor portion of the air conditioning system were observed to be damaged. This condition can reduce the efficiency of the system.
· Repair: The outdoor unit of the air conditioning system is out of level. This should be improved.
· Monitor: Low air flow was observed from the supply air ducts upon off season testing.
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:
The inspector is not required to:
A. Determine the uniformity, temperature, flow, balance,
distribution, size, capacity, BTU, or supply adequacy of the cooling system.
B. Inspect window units, through-wall units, or electronic air filters.
C. Operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit
or when other circumstances are not conducive to safe operation or may damage
the equipment.
D. Inspect or determine thermostat calibration, heat anticipation or automatic
setbacks or clocks.
E. Examine electrical current, coolant fluids or gasses, or coolant leakage
Observed Limitations:
· The air conditioning system could not be fully tested as the outside air temp was below 65 degrees F.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Attic Insulation: ·R30 Fiberglass in Main
Attic
Exterior Wall Insulation: ·None Visible
Basement Wall Insulation: ·Not Visible
Floor Cavity Insulation: ·Low Levels Suspected (But
Not Visible)
Vapor Retarders: ·None
Visible
Roof Ventilation: ·Roof Vents ·Soffit
Vents
Exhaust Fan/vent Locations: ·Bathroom ·Kitchen ·Dryer
General Comments
As is typical of homes of this age and construction, insulation levels are relatively modest. Most old homes have relatively low levels of insulation. The down side, of course, is that heating and/or cooling costs are higher. The up side is that these homes tend to be fairly well ventilated. Their natural ability to allow infiltration of outside air actually improves indoor air quality. Improving insulation levels will reduce energy costs; however, the potential benefit should we carefully weighed against the cost of improvements.
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:
· Insulation/ventilation type and levels in concealed areas are not inspected. Insulation and vapor barriers are not disturbed and no destructive tests (such as cutting openings in walls to look for insulation) are performed.
· Potentially hazardous materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be positively identified without a detailed inspection and laboratory analysis. This is beyond the scope of the inspection.
· An analysis of indoor air quality is not part of our inspection unless explicitly contracted-for and discussed in this or a separate report.
The inspector is not required to:
A. Enter the attic or unfinished spaces that are not readily
accessible or where entry could cause damage or pose a safety hazard to the
inspector in his or her opinion.
B. To move or touch insulation.
C. To move or touch vapor retarders.
D. Break or otherwise damage the surface finish or weather seal on or around
access panels and covers.
E. Identify the composition or the exact R-value of insulation material.
F. Activate thermostatically operated fans.
G. Determine the types of materials used in insulation/wrapping of pipes,
ducts, jackets, boilers, and wiring.
Observed Limitations:
· No access was gained to the wall cavities of the home.
· No access was gained to the side areas of the attic due to storage.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Water Supply Source: ·Public Water Supply
Service Pipe to House: ·Copper
Main Water Valve Location: ·Front Wall of
Basement
Interior Supply Piping: ·Copper
Waste System:
Drain, Waste, & Vent Piping: ·Plastic ·Cast
Iron
Water Heater: ·Gas
Fuel Shut-Off Valves: ·Natural Gas Main Valve At Front Wall Basement
General Comments
The plumbing system is showing signs of age. Updating the system will be required over time. The plumbing fixtures are old. Upgrading fixtures would be a logical long-term improvement. In the interim, a higher level of maintenance will likely be required.
Gas Piping
· Improve: Rust was observed on the gas piping at the main meter and in various locations.

Supply Plumbing
· Monitor: Corrosion on the exterior of the supply piping was observed in various locations.
Waste / Vent
· Repair: The trap in the main floor bathroom is leaking.
· Repair: The supply piping is corroded and barely leaking/weeping on the main water meter union and shut off.
.
Fixtures
· Monitor: The majority of plumbing fixtures are old.
· Repair: The showerhead in the powder room is in poor condition.
Improve: Main bathroom tub stop is not working.
Repair: Outside hose bibs not working (front).
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:
· Portions of the plumbing system concealed by finishes and/or storage (below sinks, etc.), below the structure, or beneath the ground surface are not inspected.
· Water quantity and water quality are not tested unless explicitly contracted-for and discussed in this or a separate report.
· Clothes washing machine connections are not inspected.
· Interiors of flues or chimneys, which are not readily accessible, are not inspected.
· Water conditioning systems, solar water heaters, fire and lawn sprinkler systems, and private waste disposal systems are not inspected unless explicitly contracted-for and discussed in this or a separate report.
The inspector is not required to:
A. Light pilot flames.
B. Determine the size, temperature, age, life expectancy or adequacy of the
water heater.
C. Inspect interiors of flues or chimneys, water softening or filtering
systems, well pumps or tanks, safety or shut-of valves, floor drains or
sprinkler systems.
D. Determine the exact flow rate, volume, pressure, temperature, or adequacy of
the water supply.
E. Determine the water quality or potability or the reliability of the water
supply or source.
F. Open closed plumbing access panels.
G. Inspect clothes washing machine connections.
H. Operate any main, branch or fixture valve except fixture faucets and hose
faucets attached to the building.
I. Test shower pans, tub and shower surrounds or enclosures for leakage.
J. Evaluate the compliance with local or state conservation or energy
standards, or the proper design or sizing of any water, waste or venting
components, fixtures or piping.
K. Determine the effectiveness of anti-siphon, back-flow prevention or drain-stop
devices.
L. Determine whether there are sufficient clean-outs for effective cleaning of
drains.
M. Evaluate gas, liquid propane or oil storage tanks.
N. Excavate or otherwise uncover the private sewage system or its components to
determine size, adequacy or efficiency.
O. Inspect water treatment systems or water filters.
P. Inspect pressure pumps or bladder tanks.
Observed Limitations:
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Wall And Ceiling Materials: ·Drywall ·Plaster
·Paneling
Floor Surfaces: ·Wood ·Vinyl/Resilient
·Tile
Window Type(s) & Glazing: ·Sliders ·Double/Single
Hung
Doors: ·Wood-Hollow Core ·Storm Door(s)
General Condition of Interior Finishes
On the whole, the interior finishes of the home are in average condition. Typical flaws were observed in some areas.
General Condition of Windows and Doors
Average Quality Doors And Windows
The windows have been lacking maintenance.
General Condition of Floors
The flooring system shows evidence of typical minor sags and unevenness.
Wall / Ceiling Finishes
· Monitor: Minor cracks were noted in various locations.
· Monitor, Repair: Possible moisture was noted on the living room ceiling. Paint has peeled in many locations.
· Monitor: Evidence of patching was detected in the basement.
· Monitor: Larger than typical cracks were noted in the basement.
Floors
· Monitor: Sagging floors are apparent in various locations.
· Repair: The tile floor is loose in front of the wood-burning stove.
Windows
· Monitor: The window(s) are inoperative in various location especially the bedrooms. Improvement can be undertaken as desired.
· Monitor: It may be desirable to replace window screens where missing in various locations. The owner should be consulted regarding any screens that may be in storage.
Doors
Repair: Backdoor window hardware is loose.
Improve: Door in basement and in various locations need trimming and hardware repairs.
Kitchen Counters
· Monitor: The kitchen counters are old. Improvement may ultimately be desirable.
Kitchen Cabinets
· Repair: Damaged kitchen cabinets should be repaired.
Basement Leakage
·
Monitor: The basement shows evidence of moisture
penetration on the front wall. It should be understood that it is
impossible to predict the severity or frequency of moisture penetration on a
one-time visit to a home. Virtually all basements exhibit signs of
moisture penetration and virtually all basements will indeed leak at some point
in time. The visible evidence is not unusual for a home of this age,
construction and location. Further monitoring of the foundation will be
required to determine what improvements, if any, will be required. Basement
leakage rarely affects the structural integrity of a home.
The vast majority of basement leakage problems are the result of insufficient
control of storm water at the surface. The ground around the house should be
sloped to encourage water to flow away from the foundations. Gutters and
downspouts should act to collect roof water and drain the water at least five
(5) feet from the foundation or into a functional storm sewer. Downspouts that
are clogged or broken below grade level, or that discharge too close to the
foundation are the most common source of basement leakage. Please refer to the
Roofing and Exterior sections of the report for more information.
In the event that basement leakage problems are experienced, lot and roof
drainage improvements should be undertaken as a first step. Please beware of
contractors who recommend expensive solutions. Excavation, damp proofing and/or
the installation of drainage tiles should be a last resort. In some cases,
however, it is necessary. Your plans for using the basement may also influence
the approach taken to curing any dampness that is experienced.

Environmental Issues
· Monitor: Radon gas is a naturally occurring gas that is invisible, odorless and tasteless. A danger exists when the gas percolates through the ground and enters a tightly enclosed structure (such as a home). Long-term exposure to high levels of radon gas can cause cancer. The Environmental Protection Agency (E.P.A.) states that a radon reading of more than 4.0 picocuries per liter of air represents a health hazard. A radon evaluation is beyond the scope of this inspection (unless specifically requested). For more information, consult the Environmental Protection Agency (E.P.A.) for further guidance and a list of testing labs in your area.
· Monitor: Carbon monoxide is a colorless, odorless gas that can result from a faulty fuel burning furnace, range, water heater, space heater or wood stove. Proper maintenance of these appliances is the best way to reduce the risk of carbon monoxide poisoning. For more information, consult the Consumer Product Safety Commission at 1-800-638-2772 (C.P.S.C.) for further guidance. It would be wise to install of carbon monoxide detectors within the home.
· Monitor: Lead based paint was in use until approximately 1978. According to the Federal Department of Housing and Urban Development, a lead hazard can be present in a house of this age. This can only be confirmed by laboratory analysis. An evaluation of lead in paint is beyond the scope of this inspection. For more information, consult the Environmental Protection Agency (E.P.A.) for further guidance and a list of testing labs in your area.
As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions
· Furniture, storage, appliances and/or wall hangings are not moved to permit inspection and may block defects.
The inspector is not required to:
A. Inspect paint, wallpaper, window treatments or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing in locations subject to human
impact.
D. Inspect security components.
E. Evaluate the fastening of countertops, cabinets, sink tops and fixtures, or
firewall compromises.
F. Move furniture, stored items, or any coverings like carpets or rugs in order
to inspect the concealed floor structure.
G. Move drop-ceiling tiles.
H. Inspect or move any household appliances.
I. Inspect or operate equipment housed in the garage except as otherwise noted.
J. Verify or certify safe operation of any auto reverse or related safety
function of a garage door.
K. Operate or evaluate security bar release and opening mechanisms, whether
interior or exterior, including compliance with local, state, or federal
standards.
L. Operate any system, appliance or component that requires the use of special
keys, codes, combinations, or devices.
M. Operate or evaluate self-cleaning oven cycles or signal lights.
N. Determine leakage from microwave ovens.
O. Operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker,
coffee-maker, can-opener, bread-warmer, blender, instant hot water dispenser,
or other small, ancillary devices.
P. Inspect elevators.
Q. Inspect central vacuums.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground, movable, freestanding, or otherwise
non-permanently installed pool/spa or self-contained equipment.
U. Come into contact with any pool or spa water in order to determine the
system structure or components.
V. Determine the adequacy of spa jet water force or bubble effect.
W. Determine the structural integrity or leakage of a pool or spa.
Fireplace:
The inspector is not required
to:
A. Inspect the vent system.
B. Inspect the interior of the chimney or flue, fire doors or screens, seals or
mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of such installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion make up devices.
I. Inspect heat distribution assists whether gravity controlled or fan
assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or firebox contents.
M. Determine adequacy of draft, perform a smoke test or dismantle or remove any
component.
Observed Limitations:
· Portions of the foundation walls were concealed from view.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Appliances Tested: ·Electric Range ·Electric
Cook top ·Dishwasher
·Waste
Disposer ·Refrigerator
Laundry Facility: ·Washer Discharges to
Laundry Tub/Sink
Other Components Tested: ·Kitchen Exhaust Fan ·Door Bell
General Comments
The appliances are old units that are approaching the end of their serviceable life. While replacement is not needed right away, it would be wise to budget for new appliances. In the interim, a higher level of maintenance can be expected.
Electric Range
· Monitor: The electric range is an old unit. While replacement is not needed right away, it would be wise to budget for a new range. In the interim, a higher level of maintenance can be expected.
Electric Cook top
· Monitor: The electric cook top is an old unit. While replacement is not needed right away, it would be wise to budget for a new cook top. In the interim, a higher level of maintenance can be expected.
Dishwasher
· Monitor: The dishwasher is an old unit. While replacement is not needed right away, it would be wise to budget for a new dishwasher. In the interim, a higher level of maintenance can be expected.
Waste Disposer
· Monitor: The waste disposer is excessively noisy.
As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions
· Thermostats, timers and other specialized features and controls are not tested.
· The temperature calibration, functionality of timers, effectiveness, efficiency and overall performance of appliances is outside the scope of this inspection.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.